       signal action siglist ?command?

              Warning:    The  behavior  of  signals  under  Unix
              doesn't make signals  a  general  event  mechanism.
              Interrupted  system  calls,  caused by signals, can
              cause errors in code where they are  not  expected.
              This  can  cause  a program to behave in unexpected
              ways.  In general, the only safe usage for  signals
              is to generate errors to terminate a blocked opera-
              tion.

              Specify the action to take when a  Unix  signal  is
              received  by Extended Tcl, or a program that embeds
              it.  Siglist is a list of either  the  symbolic  or
              numeric  Unix  signal (the SIG prefix is optional).
              Action is one of the following actions to  be  per-
              formed  on  receipt  of the signal.  To specify all
              modifiable signals, use `*' (this will not  include
              SIGKILL  and SIGSTOP, as they can not be modified).

              default
                     Perform system default action when signal is
                     received  (see signal system call documenta-
                     tion).

              ignore Ignore the signal.

              error  Generate a catchable Tcl error.  It will  be
                     as  if the command that was running returned
                     an error.  The error code  will  be  in  the
                     form:
                          POSIX SIG signame
                     For  the death of child signal, signame will
                     always be SIGCHLD, rather  than  SIGCLD,  to
                     allow writing portable code.

              trap   When  the signal occurs, execute command and
                     continue  execution  if  an  error  is   not
                     returned  by  command.   The command will be
                     executed in the global context.  The command
                     will  be  edited before execution, replacing
                     occurrences of "%S" with  the  signal  name.
                     Occurrences  of "%%" result in a single "%".
                     This editing occurs  just  before  the  trap
                     command   is  evaluated.   If  an  error  is
                     returned, then follow the standard Tcl error
                     mechanism.   Often  command  will just do an
                     exit.

              get    Retrieve the current settings of the  speci-
                     fied signals.  A keyed list will be returned
                     were the keys are one of the specified  sig-
                     nals and the values are a list consisting of
                     the action associated with the signal,  a  0
                     if  the  signal may be delivered (not block)
                     and a 1 if it is blocked. The actions  maybe
                     one   of   `default',`ignore',   `error'  or
                     `trap'.  If the action is  trap,  the  third
                     element  is  the command associated with the
                     action.  The action `unknown' is returned if
                     a non-Tcl signal handler has been associated
                     with the signal.

              set    Set signals from a keyed list in the  format
                     returned  by  the  get.   For  this  action,
                     siglist is the keyed list of  signal  state.
                     Signals  with an action of `unknown' are not
                     modified.

              block  Block  the  specified  signals  from   being
                     received. (Posix systems only).

              unblock
                     Allow  the  specified signal to be received.
                     Pending signals will not occur. (Posix  sys-
                     tems only).

              The  signal  action  will  remain enabled after the
              specified signal has occurred.   The  exception  to
              this  is  SIGCHLD on systems without Posix signals.
              For these systems, SIGCHLD is not be  automatically
              reenabled.   After  a SIGCHLD signal is received, a
              call to wait must be performed to retrieve the exit
              status  of the child process before issuing another
              signal SIGCHLD ... command.  For code that is to be
              portable  between  both  types of systems, use this
              approach.

              Signals are not processed until after  the  comple-
              tion  of the Tcl command that is executing when the
              signal is received.  If an interactive Tcl shell is
              running, then the SIGINT will be set to error, non-
              interactive Tcl  sessions  leave  SIGINT  unchanged
              from when the process started (normally default for
              foreground processes and ignore  for  processes  in
              the background).

              This command is provided by Extended Tcl.