PKTC-EVENT-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    Integer32,
    Unsigned32,
    NOTIFICATION-TYPE
	--	BITS
    							FROM SNMPv2-SMI
    TruthValue, DisplayString, DateAndTime
    							FROM SNMPv2-TC
    OBJECT-GROUP,
    MODULE-COMPLIANCE				FROM SNMPv2-CONF
    InetAddressType, InetAddress
                                               FROM INET-ADDRESS-MIB
	NOTIFICATION-GROUP
    							FROM SNMPv2-CONF
clabProjPacketCable
  							    	FROM CLAB-DEF-MIB;
pktcEventMib MODULE-IDENTITY
    LAST-UPDATED    "0203080000Z" -- 03/08/02
    ORGANIZATION    "Packet Cable Provisioning/OSS Group"
    CONTACT-INFO
     "Matt Osman
            Postal: Cable Television Laboratories, Inc.
			400 Centennial Parkway
			Louisville, Colorado 80027-1266
            U.S.A.
            Phone:  +1 303-661-9100
            Fax:    +1 303-661-9199
            E-mail: m.osman@cablelabs.com"
    DESCRIPTION
            "This MIB module supplies the basic management objects
            for event reporting

            Acknowledgements:
            Rick Vetter		-	Motorola
     Eugene Nechamkin	-	Broadcom"
    ::=  { clabProjPacketCable 3 }

--
--
pktcDevEventControl		OBJECT IDENTIFIER ::= { pktcEventMib 1 }
pktcDevEventConfig	  	OBJECT IDENTIFIER ::= { pktcEventMib 2 }
pktcDevEventThrottle	OBJECT IDENTIFIER ::= { pktcEventMib 3 }
pktcDevEventLocal		OBJECT IDENTIFIER ::= { pktcEventMib 4 }
pktcDevEventNotify		OBJECT IDENTIFIER ::= { pktcEventMib 5 }
pktcDevEvNotification 	OBJECT IDENTIFIER ::= { pktcEventMib 6 0 }

--
--  Event Reporting
--

--
--	Event reporting control
--
pktcDevEvControl OBJECT-TYPE
    SYNTAX INTEGER {
            resetLog(1),
            setDefaults(2),
            useConfigured(3)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
             "This object defines actions related to the event log configuration.
             Setting this object to resetLog(1) empties the event log.
             All event log data is deleted. Setting it to setDefault(2)
             restores all event priorities to their factory-default
             reporting parameters. Setting it to useConfigured(3) reloads
             previously configured parameters."
    ::= { pktcDevEventControl 1 }

    pktcDevEvControlState OBJECT-TYPE
        SYNTAX INTEGER {
            logReset(1),
            defaultsSet(2),
            userConfigured(3),
            processing(4)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This object reflects the state of the device as modified in
             pktcDevEvControl. Processing indicates that a state change
             is underway. This object reflects the state of the device."
    ::= { pktcDevEventControl 2 }

pktcDevEvSyslogAddressType OBJECT-TYPE
    SYNTAX      InetAddressType
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "The type of Internet address of the Syslog server.
             Not all address types may be supported."
    ::= { pktcDevEventControl 3 }

pktcDevEvSyslogAddress OBJECT-TYPE
    SYNTAX      InetAddress
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "The IP address of the Syslog server. If 0.0.0.0,
             syslog transmission is inhibited. The use of FQDNs is
             syntactically allowed but it is discouraged for syslog
             servers since not resolving them in a timely manner
             may leave the device without access to the Syslog
             daemon during critical network events."
    ::= { pktcDevEventControl 4 }

pktcDevEvSyslogUdpPort OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The UDP port number the syslog device is using to send
         requests to the syslog server."
    DEFVAL  {514}
    ::= { pktcDevEventControl 5 }

--
--	Event throttling control
--
pktcDevEvThrottleAdminStatus OBJECT-TYPE
    SYNTAX INTEGER {
            throttlingInhibited(1),
            dynamicThresholding(2),
            manualThresholding(3),
            eventsInhibited(4)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "Controls the transmission of traps and syslog messages
             with respect to the trap pacing threshold.
             throttlingInhibited(1) causes traps and syslog messages to be
             transmitted without regard to the threshold settings.
             dynamicThresholding(2) causes trap transmission and
             syslog messages to be suppressed if the number of traps
             would otherwise exceed the threshold.
             manualThresholding(3) causes trap transmission to cease
             at the threshold, and not resume until directed to do so.
             eventsInhibited(4) causes all trap transmission and syslog
             messages to be suppressed.

             A single event is always treated as a single event for
             threshold counting. That is, an event causing both a trap
             and a syslog message is still treated as a single event.

             Writing to this object resets the thresholding state.

             At initial startup, this object has a default value of
             throttlingInhibited(1)."
     DEFVAL { throttlingInhibited }
    ::= { pktcDevEventThrottle 1 }

pktcDevEvThrottleInhibited OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "If true(1), trap/inform and syslog transmission is currently
             inhibited due to thresholds and/or the current setting of
             pktcDevEvThrottleAdminStatus. In addition, this is set to
             true(1) if transmission is inhibited due to no
             syslog (pktcDevEvSyslogAddress) or trap/inform
             (pktcMtaDevSnmpEntity)
             destinations having been set."
    ::= { pktcDevEventThrottle 2 }

pktcDevEvThrottleThreshold OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "Number of trap/syslog events per pktcDevEvThrottleInterval
             to be transmitted before throttling.

             A single event is always treated as a single event for
             Threshold counting. That is, an event causing both a
trap/inform and a syslog message is still treated as a
single event.

             At initial startup, this object returns 2."
     DEFVAL { 2 }
    ::= { pktcDevEventThrottle 3 }

pktcDevEvThrottleInterval OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "The interval over which the throttle threshold applies.
             At initial startup, this object has a value of 1."
    DEFVAL { 1 }
    ::= { pktcDevEventThrottle 4 }

--
-- Event configuration
--
--
-- The following table configures the reporting of the various programmable
-- events.
--
pktcDevEvProgrammableTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PktcDevEvProgrammableEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "This table allows control of the reporting of event classes.
        For each event priority, a combination of logging and
        reporting mechanisms may be chosen. The mapping of event types
        to priorities is vendor-dependent. Vendors may also choose to
        allow the user to control that mapping through proprietary means."
    ::= {  pktcDevEventConfig 1 }

pktcDevEvProgrammableEntry OBJECT-TYPE
    SYNTAX      PktcDevEvProgrammableEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "Allows configuration of the reporting mechanisms for a
             programmable event, including level, report type, and text."
    INDEX { pktcDevEvProgrammableId, pktcDevEvProgrammableEnterprise }
    ::= { pktcDevEvProgrammableTable 1 }

PktcDevEvProgrammableEntry ::= SEQUENCE {
    pktcDevEvProgrammableId		  	Integer32,
    pktcDevEvProgrammableEnterprise	  	Integer32,
    pktcDevEvProgrammableLevel     	  	INTEGER,
    pktcDevEvProgrammableReporting       	BITS,
    pktcDevEvProgrammableText 			DisplayString

    }

pktcDevEvProgrammableId OBJECT-TYPE
    SYNTAX Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
"ID for a specific programmable event to which the priority and display string are matched. These Event Ids are vendor specific or in the case of PacketCable events defined in pkt-tr-memevent-id-v01-001128."
    ::= { pktcDevEvProgrammableEntry 1 }

pktcDevEvProgrammableEnterprise	OBJECT-TYPE
    SYNTAX      Integer32  (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
"Provides the IANA enterprise number of the device manufacturer for proprietary events, and the CableLabs IANA enterprise number for PacketCable specified events."
    ::= { pktcDevEvProgrammableEntry 2 }

pktcDevEvProgrammableLevel OBJECT-TYPE
    SYNTAX INTEGER {
            critical(1),
            major(2),
            minor(3),
            warning(4),
            information(5)

    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "The priority level that is controlled by this entry. These
            are ordered from most (critical) to least (information) critical.
            Each event has a particular priority level associated with it (as
            defined by the vendor). The levels are described as:

            critical(1)  A service-affecting condition that requires immediate
                          corrective action.
            major(2)     A service-affecting condition that requires urgent
                          corrective action.
            minor(3)     A non-service-affecting fault condition which warrants
                          corrective action in order to avoid a more serious fault.
            warning(4)   A potential or impending condition which can lead to a
                          fault;  diagnostic action is suggested.
            information(5)  Normal event meant to convey information."
   ::= { pktcDevEvProgrammableEntry 3 }

pktcDevEvProgrammableReporting OBJECT-TYPE
        SYNTAX BITS {
            local(0),
            traps(1),
            syslog(2),
		inform(3),
		none(4)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Defines the action to be taken on occurrence of this
             event class. Implementations may not necessarily support
             all options for all event classes, but at minimum must
             allow traps and syslogging to be disabled. If the
             local(0) bit is set, then log to the internal log, if the
             traps(1) bit is set, then generate a trap, if the
             syslog(2) bit is set, then send a syslog message
             (assuming the syslog address is set)
		   inform(3) bit is set, then generate an inform, if the
		   none(4) bit is set, then this event is not generated."
--      DEFVAL { local }
        ::= { pktcDevEvProgrammableEntry 4 }

pktcDevEvProgrammableText OBJECT-TYPE
    SYNTAX DisplayString(SIZE (127))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "Programmable event display string providing a human-readable
             description of the event."
    ::= { pktcDevEvProgrammableEntry 5 }

-- The following table configures the reporting of the various fixed
-- events.
--
pktcDevEvFixedTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PktcDevEvFixedEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table allows control of the reporting of event classes.
        For each event priority, a combination of logging and
        reporting mechanisms may be chosen. The mapping of event types
        to priorities is vendor-dependent. Vendors may also choose to
        allow the user to control that mapping through proprietary means."
    ::= {  pktcDevEventConfig 2 }

pktcDevEvFixedEntry OBJECT-TYPE
    SYNTAX      PktcDevEvFixedEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "Allows configuration of the reporting mechanisms for a
             fixed event, including level, and report type."
    INDEX { pktcDevEvFixedId, pktcDevEvFixedEnterprise }
    ::= { pktcDevEvFixedTable 1 }

PktcDevEvFixedEntry ::= SEQUENCE {
    pktcDevEvFixedId		  Integer32,
    pktcDevEvFixedEnterprise 	  Integer32,
    pktcDevEvFixedLevel     	  INTEGER,
    pktcDevEvFixedReporting     	  BITS,
    pktcDevEvFixedText 		  DisplayString
    }

pktcDevEvFixedId OBJECT-TYPE
    SYNTAX Integer32  (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
"ID for a specific fixed event to which the priority and display string are matched. These Event Ids are vendor specific or in the case of PacketCable events defined in pkt-tr-memevent-id-v01-001128."
    ::= { pktcDevEvFixedEntry 1 }

pktcDevEvFixedEnterprise	OBJECT-TYPE
    SYNTAX      Integer32  (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Provides the IANA enterprise number of the device manufacturer for
		proprietary events, and the CableLabs IANA enterprise number for
		PacketCable specified events."
    ::= { pktcDevEvFixedEntry 2 }

pktcDevEvFixedLevel OBJECT-TYPE
    SYNTAX INTEGER {
            critical(1),
            major(2),
            minor(3),
            warning(4),
            information(5)

    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "The priority level that is controlled by this entry. These
            are ordered from most (critical) to least (information) critical.
            Each event has a particular priority level associated with it (as
            defined by the vendor). The levels are described as:

            critical(1)     A service-affecting condition that requires immediate
                             corrective action.
            major(2)        A service-affecting condition that requires urgent
                             corrective action.
            minor(3)        A non-service-affecting fault condition which warrants
                             corrective action in order to avoid a more serious fault.
            warning(4)      A potential or impending condition which can lead to a
                             fault; diagnostic action is suggested.
            information(5)  Normal event meant to convey information."
    ::= { pktcDevEvFixedEntry 3 }

pktcDevEvFixedReporting OBJECT-TYPE
        SYNTAX BITS {
            local(0),
            traps(1),
            syslog(2),
		  inform(3),
		  none(4)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
             "Defines the action to be taken on occurrence of this event
              class. Implementations may not necessarily support all options
              for all event classes, but at minimum must allow traps and syslogging
              to be disabled. If the local(0) bit is set, then log to the internal
              log, if the traps(1) bit is set, then generate a trap, if the syslog(2)
              bit is set, then send a syslog message (assuming the syslog address is
              set) inform(3) bit is set, then generate an inform, if the none(4) bit
              is set, then this event is not generated."
--	  DEFVAL { local }
        ::= { pktcDevEvFixedEntry 4 }

pktcDevEvFixedText OBJECT-TYPE
    SYNTAX DisplayString(SIZE (127))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Fixed event display string providing a human-readable
             description of the event."
    ::= { pktcDevEvFixedEntry 5 }

--
-- Local event table - for retrieval of events via SNMP
--

pktcDevEventTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PktcDevEventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "Contains a log of network and device events that may be
             of interest in fault isolation and troubleshooting."
    ::= {  pktcDevEventLocal 1 }

pktcDevEventEntry OBJECT-TYPE
    SYNTAX      PktcDevEventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "Describes a network or device event that may be of
             interest in fault isolation and troubleshooting.
             Entries are created with the first occurrence of an event.
             pktcDevEvControl can be used to clear the table.
             Individual events can not be deleted."
    INDEX { pktcDevEvIndex }
    ::= { pktcDevEventTable 1 }

PktcDevEventEntry ::= SEQUENCE {
           	pktcDevEvIndex           	INTEGER,
	     	pktcDevEvTime			DateAndTime,
            	pktcDevEvLevel           	INTEGER,
	     	pktcDevEvEnterprise		Integer32,
            	pktcDevEvId              	Unsigned32,
           	pktcDevEvText            	DisplayString,
	    	pktcDevEvMacAddress		OCTET STRING,
	      	pktcDevEvEndpointName	DisplayString
        }

pktcDevEvIndex OBJECT-TYPE
    SYNTAX      INTEGER (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Provides relative ordering of the objects in the event
            log. This object will always increase except when
            (a) the log is reset via pktcDevEvControl,
            (b) the device reboots and does not implement non-volatile
            storage for this log, or (c) it reaches the value 2^31.
            The next entry for all the above cases is 1. This also serves as
		  a indicator of event sequence."
    ::= { pktcDevEventEntry 1 }

pktcDevEvTime		OBJECT-TYPE
    SYNTAX      	DateAndTime
    MAX-ACCESS  	read-only
    STATUS      	current
    DESCRIPTION
            "Provides a human-readable description of the
time at which the event occurred."
    ::= { pktcDevEventEntry 2 }

pktcDevEvLevel OBJECT-TYPE
    SYNTAX INTEGER {
            critical(1),
            major(2),
            minor(3),
            warning(4),
            information(5)

    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The priority level of this event as defined by the
             vendor.  These are ordered from most serious (critical)
             to least serious (debug)."
    ::= { pktcDevEventEntry 3 }

   pktcDevEvEnterprise	OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Provides the IANA enterprise number of the device manufacturer for
		proprietary events, and the CableLabs IANA enterprise number for
		PacketCable specified events."
    ::= { pktcDevEventEntry 4 }

pktcDevEvId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
          "ID for a specific event to which the priority and display string are
           matched. These Event Ids are vendor specific or in the case of
           PacketCable events defined in pkt-tr-memevent-id-v01-001128."
    ::= { pktcDevEventEntry 5 }

pktcDevEvText OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Provides a human-readable description of the event,
             including all relevant context (interface numbers,
             etc.)."
    ::= { pktcDevEventEntry 6 }

   pktcDevEvMacAddress	 OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Provides the MAC address of the device generating the event."
    ::= { pktcDevEventEntry 7 }

    pktcDevEvEndpointName	 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This is the endpoint identifier followed by the FQDN/IP Address
             of the device. This is in the form - AALN/X:FQDN/IP Address.
             If the event is not specific to an endpoint, then the contents
             is just the FQDN/IP address."
    ::= { pktcDevEventEntry 8 }

--
--	Event Data for Traps - Informs
--
    pktcDevEvReportIndex           OBJECT-TYPE
    SYNTAX      Integer32  (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Integer value starting at one that increases by one
             for each event generated. Used for sequencing of events."
    ::= { pktcDevEventNotify 1 }

   pktcDevEvReportTime		OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Provides a human-readable description of the time at
			which the event occurred."
    ::= { pktcDevEventNotify 2 }

    pktcDevEvReportLevel           OBJECT-TYPE
    SYNTAX      INTEGER {
      critical(1),
      major(2),
      minor(3),
      warning(4),
      information(5)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The priority level of this event as defined by the
             vendor.  These are ordered from most serious (critical)
             to least serious (debug)."
    ::= { pktcDevEventNotify 3 }

   pktcDevEvReportEnterprise	OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Provides the IANA enterprise number of the device
          	manufacturer for proprietary events, and the CableLabs
          	IANA enterprise number for
		PacketCable specified events."
    ::= { pktcDevEventNotify 4 }

    pktcDevEvReportId              OBJECT-TYPE
      SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "ID for a specific event to which the priority and display string
          are matched. These Event Ids are vendor specific or in the case of
          PacketCable events defined in pkt-tr-memevent-id-v01-001128."
    ::= { pktcDevEventNotify 5 }

    pktcDevEvReportText             OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Provides a human-readable description of the event,
             including all relevant context (interface numbers,
             etc.)."
    ::= { pktcDevEventNotify 6 }

   pktcDevEvReportMacAddress	 OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
          "Provides the MAC address of the device generating the event."
    ::= { pktcDevEventNotify 7 }

    pktcDevEvReportEndpointName	 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
          "This is the endpoint identifier followed by the FQDN/IP Address of the
           device. in the case of the , this is in the form - AALN/X:FQDN/IP
           Address. If the event is not specific to an endpoint, then the contents
           is just the FQDN/IP address"
    ::= { pktcDevEventNotify 8 }

   pktcDevEvInform NOTIFICATION-TYPE
	OBJECTS { pktcDevEvReportIndex, pktcDevEvReportTime,pktcDevEvReportLevel,
	    pktcDevEvReportEnterprise,pktcDevEvReportId,pktcDevEvReportText,
	    pktcDevEvReportMacAddress,pktcDevEvReportEndpointName }
	STATUS      current
        DESCRIPTION
		"Inform for event reporting "
	::= { pktcDevEvNotification 1 }

   pktcDevEvTrap NOTIFICATION-TYPE
	OBJECTS { pktcDevEvReportIndex, pktcDevEvReportTime,pktcDevEvReportLevel,
	    pktcDevEvReportEnterprise,pktcDevEvReportId,pktcDevEvReportText,
	    pktcDevEvReportMacAddress,pktcDevEvReportEndpointName }
	STATUS      current
        DESCRIPTION
		" Trap for event reporting "
	::= { pktcDevEvNotification 2 }

pktcEventConformance  OBJECT IDENTIFIER ::= { pktcEventMib 7 }
pktcEventCompliances  OBJECT IDENTIFIER ::= { pktcEventConformance 1 }
pktcEventGroups       OBJECT IDENTIFIER ::= { pktcEventConformance 2 }

-- compliance statements

pktcEventBasicCompliance MODULE-COMPLIANCE
    STATUS     current
    DESCRIPTION
            "The compliance statement for devices that implement
             Event reporting feature."
    MODULE   --pktcEventMib

-- unconditionally mandatory groups

    MANDATORY-GROUPS {
            pktcEventGroup
    }

-- units of conformance

::= { pktcEventCompliances 3 }

pktcEventGroup OBJECT-GROUP
    OBJECTS {
        	pktcDevEvControl,
        	pktcDevEvControlState,
        	pktcDevEvSyslogAddressType,
        	pktcDevEvSyslogAddress,
        	pktcDevEvSyslogUdpPort,
        	pktcDevEvThrottleAdminStatus,
        	pktcDevEvThrottleInhibited,
        	pktcDevEvThrottleThreshold,
        	pktcDevEvThrottleInterval,
  		pktcDevEvProgrammableEnterprise,
    		pktcDevEvProgrammableLevel,
    		pktcDevEvProgrammableReporting,
    		pktcDevEvProgrammableText,
    		pktcDevEvFixedEnterprise,
    		pktcDevEvFixedLevel,
    		pktcDevEvFixedReporting,
    		pktcDevEvFixedText,
          	pktcDevEvIndex,
	     	pktcDevEvTime,
        	pktcDevEvLevel,
	    	pktcDevEvEnterprise,
        	pktcDevEvId,
        	pktcDevEvText,
	    	pktcDevEvMacAddress,
	    	pktcDevEvEndpointName,
		pktcDevEvReportIndex,
		pktcDevEvReportTime,
 		pktcDevEvReportLevel,
		pktcDevEvReportEnterprise,
		pktcDevEvReportId,
    		pktcDevEvReportText,
    		pktcDevEvReportMacAddress,
    		pktcDevEvReportEndpointName
    }
    STATUS    current
    DESCRIPTION
        "Group of objects for PacketCable Event MIB."
    ::= { pktcEventGroups 1 }

-- Notification Group Added

pktcEventNotificationGroup		NOTIFICATION-GROUP
	NOTIFICATIONS { pktcDevEvInform, pktcDevEvTrap }
	STATUS	current
	DESCRIPTION
		"These notifications deal with change in status of
		MTA Device."
	::= { pktcEventGroups 2 }

END